Wire rope breaking force: reference data, calculation and WLL

Compare four clearly scoped reference rows and understand why a calculation or breaking-force value is not a working load rating.

Reference table

Scroll horizontally to view the full table →

External reference only: Deacon AISI 316, 1570 N/mm², WSC rope
ConstructionNominal diameter (mm)Published MBL (kN)
7×73.005.48
7×74.009.75
7×193.005.12
7×194.009.09

These four values are from Deacon’s cited product tables, not HTWR test results, stock specifications or a certification claim. Obtain the documented value for the actual supplied rope. Sources and scope ↗

Download reference CSV ↓

A reproducible calculation example

The existing estimator uses F (kN) = K × d² × R / 1000. For its 7×7 / 316 / WSC configuration, K = 0.388, d = 4 mm and R = 1570 N/mm² give 9.74656 kN, displayed as 9.747 kN. The cited table rounds its value to 9.75 kN. K is an approximate inferred coefficient for this configuration, not a universal constant.

Ask for the complete assembly basis

Record the rope specification, terminations, intended loading, inspection requirements and applicable design basis. Do not assume one generic divisor establishes a WLL for every application. The estimator does not model wear, corrosion, bending or dynamic loading.

Common questions

Why is the table slightly different from the calculator?

The calculator uses a rounded, inferred coefficient. A published product table and its rounding need not exactly match that approximation.

Can I use the same coefficient for stainless and galvanised rope?

Do not transfer a coefficient without matching its documented construction, material, core and strength-grade scope. Use the tool’s explicitly supported configuration.

Sources and scope

Reference information supports specification discussions. Confirm the actual supplied product and acceptance criteria with the manufacturing team.